QuatGrad Analytical HPLC
The QuatGrad? Analytical HPLC features a modular design integrating a quaternary gradient pump, autosampler, column oven and multiple detectors for precise analysis.Its gradient pump ensures accurate elution and high reproducibility.The autosampler with needle wash delivers high injection accuracy and low cross-contamination.Precise temperature control optimizes separation and stability.Multiple detectors support diverse applications.Compact and user-friendly, it meets strict demands for research and quality control.
Online Buy

Introduction

The QuatGrad? Analytical HPLC features a modular design integrating a quaternary gradient pump, autosampler, column oven and multiple detectors for precise analysis.Its gradient pump ensures accurate elution and high reproducibility.The autosampler with needle wash delivers high injection accuracy and low cross-contamination.Precise temperature control optimizes separation and stability.Multiple detectors support diverse applications.Compact and user-friendly, it meets strict demands for research and quality control.


Feature

1.?Ultra-high pressure quaternary pump (max. 10,500 PSI), compatible with high-resolution columns for fast analysis.

2.?Excellent pressure stability with pulse suppression (<10 PSI), delivering stable baseline.

3.?Flexible solvent mixing for complex gradient elution.

4.?High-precision autosampler with low carryover ensures reliable quantification.

5.?High-capacity sample tray (2×54 vials / 2×96-well plates), with optional cooling.

6.?Precise column temperature control improves separation repeatability.

7.?Compact modular system with intuitive operation for research and QC.


Specification


Pump

Model No.

P42

P42T

P40

P40T

P40P

P40N

Type

Quaternary Pump

Bio-compatible Quaternary Low-pressure Gradient Pump

Normal Phase Quaternary Low-pressure Gradient Pump

Gradient Mode

Quaternary Gradient

Quaternary low-pressure gradient

Online Degassing

Standard 5-channel

Standard 4-channel

Max. Pressure

10,500 PSI

(@0-2mL/min)

6,000 PSI

(@2-5mL/min)

3,000 PSI

(@5-10mL/min

6,000 PSI

(@0-5mL/min)

3,000 PSI

(@5-10mL/min)

5,000 PSI

(@0-5mL/min)

3,000 PSI

(@5-10mL/min )

5,000 PSI

(@0-2mL/min)

3500 PSI

(@2-5mL/min)

3,000 PSI

(@5-10mL/min)

?

Flow Rate Range

0.01 mL/min - 10.000 mL/min (Increment?0.001mL/min)

Flow?Accuracy

±0.5% (@1mL/minH2O

Flow?Precision

0.1% (@1mL/minH2O)(JJG)

0.06% RSD (@1mL/minH2O) (ASTM)

Gradient Accuracy

±0.5%

Gradient Repeatability

0.2% SD

Autosampler

Model No.

A10

A20

A50

A30

Type

Standard

Ultra-high Pressure

Large-volume Injection

Preparative

Injection Mode

Suction mode (full loop injection / partial injection / microliter carryover injection)

Loop Volume

100μL20μL/50 μL?Optional

1ml

5ml

Maximum sample volume

Full Loop Injection?= Loop Volume

Partial Injection?= 1/2Loop Volume

Microliter Carryover Injection?=Loop Volume?- 3 ×needle?Volume/2

Sample Capacity

2×54 1.5mL 108-position sample vials?or?2×96-well plate

2×15 5mL vial rack

Injection Repeatability

Full Loop Injection≤0.3% RSD

Partial Injection≤0.3% RSD (≥5μL)

≤0.5% RSD (≥2μL)

Microliter Carryover Injection≤1.0% RSD

Cross Contamination

<0.0025% (Under Specified Conditions)

Refrigeration Function (Optional)

Upper limit: Ambient temperature -?5 °C

Lower limit: Ambient temperature -?21 °C, minimum 4 °C

Step: 0.1 °C

Column Oven

Model

C10/C15

C12/C16

Type

Standard Heating Type

Heating & Cooling Type

Temperature Control Type

Forced Air Circulation

Peltier Temperature Control

Temperature Control Range

Ambient +5℃?– 85 ℃

High Temperature: 85 ℃

Low Temperature: Ambient ?20 ℃?or ?5 ℃, minimum 4 ℃

Temperature Accuracy

±1.0℃

Temperature Stability

±0.1℃

Column Capacity

4 × 300 mm columns or more shorter columns

UV-Vis Detector

Model

D08

D10/D15

Wavelength range

190 nm - 600 nm

190 nm - 900 nm

Light source

Deuterium lamp

Deuterium lampTungsten lamp

Spectral bandwidth

8 nm

Wavelength accuracy

±1 nm

Wavelength precision

0.1 nm

Noise

±5.0×10-6AU (JJG)

±3.5×10-6AU (ASTM)

Drift

1×10-4?AU/Hr


Related to recommend